Previous
Next
FCT-VS Dryers
The FCT VS range was created to meet the latest energy saving and low environmental impact market demands.
Features
Technical Data
Main Components
Features
WHY CHOOSE THE FCT-VS DRYERS
The FCT VS range focuses on energy efficiency and minimal environmental impact, blending FCT’s eco-friendly gas approach with ACT VS’s inverter technology for optimal performance. It features:
- R513A refrigerant gas for reduced environmental footprint.
- Variable speed operation to adjust power input based on need.
- Benefits include increased eco-friendliness, lower operational costs, and enhanced efficiency across all conditions.
MAXIMUM OPERATING CONDITIONS:
- Ambient temperature up to +45°C.
- Inlet air pressure up to 14 barg.
- Inlet air temperature up to +70°C.
Technical Data
Model | Refrigerant | Flow rate | Power Supply | Connections | ||||
[Type] | [m3/h] | [l/min] | [scfm] | [Ph/Volt/Fr] | [ Ø ] | |||
FCT 210 VS | R 513A | 1 260 | 21 000 | 742 | 3/400/50-60 | DN80 PN16 | ||
FCT 300 VS | R 513A | 1 800 | 30 000 | 1 060 | 3/400/50-60 | DN80 PN16 | ||
FCT 360 VS | R 513A | 2 208 | 36 800 | 1 300 | 3/400/50-60 | DN80 PN16 | ||
FCT 400 VS | R 513A | 2 400 | 40 000 | 1 413 | 3/400/50-60 | DN100 PN16 | ||
FCT 500 VS | R 513A | 3 000 | 50 000 | 1 766 | 3/400/50-60 | DN100 PN16 | ||
FCT 600 VS | R 513A | 3 600 | 60 000 | 2 119 | 3/400/50-60 | DN100 PN16 | ||
FCT 720 VS | R 513A | 4 416 | 73 600 | 2 600 | 3/400/50-60 | DN100 PN16 | ||
FCT 900 VS | R 513A | 5 400 | 90 000 | 3 178 | 3/400/50 | DN150 PN16 | ||
FCT 1100 VS | R 513A | 6 624 | 110 400 | 3 900 | 3/400/50 | DN150 PN16 | ||
FCT 1200 VS | R 513A | 7 200 | 120 000 | 4 238 | 3/400/50 | DN200 PN16 | ||
FCT 1500 VS | R 513A | 8 832 | 147 200 | 5 200 | 3/400/50 | DN200 PN16 |
Data refer to the following nominal condition: ambient temperature + 25 °C; inlet air pressure 7 barg; inlet air temperature +35 °C.
Main Components
- ALU DRY Aluminum Heat Exchanger
- Highly Efficient Compressor
- Large-Capacity Condenser Unit
- Water-Cooled Pressure Switch Valve
- DMC34 Digital Controller with RS485 Modbus Connectivity
- Thermal or Thermo-Ammeter Protection for the Refrigerant Compressor
- Automated Control for Condensation Pressure
- Protection Against High Temperatures in Compressors
- Phase Sequence Relay Protection for Refrigerant Compressor (applicable to 3ph models)
- Safety Switches for Refrigerant Pressure, both High and Low
- Electronic Expansion Valve
- Electronic Hot Gas Bypass Valve
- Electronic System for Draining Condensation
- Heating System for the Compressor Crankcase (exclusive to 3ph models)
- Models with Customizable Power Supply and Connection Types [Ph/V/Hz] Available by Request
- Includes Counter-Flanges and Gaskets conforming to EN 1092-1 Standards.